Cyber TM
|
Category: |
Surgery, Laser systems |
|
{{variant.name}}:
|
{{opt.name}}
{{opt.name}}
|
Cyber TM represents the family of high power Thulium laser (150W e 200W) dedicated to BPH
and urology treatments, together with other soft tissue surgery in many other medical specialties. Its 2
μm radiation is strongly absorbed by water (highly present in all tissues), making its cutting and
vaporization speed relatively constant during the procedure regardless of tissue vascularization.
Furthermore, this wavelength results in extremely reduced depth of penetration (0.1-0.2 mm), efficient
tissue ablation and effective hemostasis.
Supreme BPH versatility
Enucleation and Vaporization of the adenoma are available with the same device, without constraints
in technique selection.
Thulium enucleation technique is not dependent on the size, highly customizable, with the possibility to
switch quickly from cutting to coagulation thanks to the double footswitch. On the other hand, Thulium
vaporization is an easy and intuitive procedure, obviating the use of morcellator, taking advantage of the
maximum power of this device for faster treatments. Alternatively, vaporesection technique can be
effectively performed to skip the morcellation phase.
The highest power
Cyber TM represents the thulium surgical laser featured with the greatest output power on the market:
200W.
This emission power, coupled with the 1000µm fiber, enables the fastest vaporization of the adenoma
thanks to the powerful ablation on very large areas.
Confined Damage
and Superior Hemostasis
The 2 µm radiation is strongly absorbed by water, resulting in minimal depth of penetration (0.1-0.2
mm), with no alteration of tissue layers beyond the surface (on the side, tissue appearance after
24hours upon vaporization). This interaction results in precise cut and ablation, providing the surgeon
with a high degree of control and reducing the risk of inadvertent injury substantially. Thulium
wavelength enhances hemostatic effectiveness already while cutting as well.
Established Technology
Cyber TM device is a well-established laser technology on the global market. As demonstrated by its
long presence on the market, (introduced in 2009) and over 300 installations worldwide in more than 25
different countries, this device represents a reliable and highly effective surgical solution for a large
variety of surgical treatments.
Superior Multidisciplinarity
Thanks to its unique laser properties and minimal damage, Thulium laser allows effective excision,
cutting, ablation and coagulation of soft tissues in different medical specialties.
Apart from Urology, Cyber TM can be used in Thoracic Surgery, Partial
Nephrectomy, Gastroenterology, ENT, General Surgery, Gynecology.
Based on that, this laser device can address multiple needs from different wards of the same hospital.
Thoracic and GI Surgery
Use of Thulium laser was proven to be effective not only in the urology field, but also in the thoracic
field (for precise cutting in lung resection and endobronchial ablation) and in the gastroenterology
field (with its ablation and coagulation effectiveness coming in handy as an alternative to APC surgery).
Some of these laser applications are detailed in published studies with Cyber TM.
Clinical Evidences
Since its introduction to the market, use of Cyber TM device has been reported in multiple publications
by different institutions. These publications and research activities provide strong clinical evidences
regarding the safety and effectiveness of Cyber TM laser within different medical fields. Indeed, more
than 50 publications detail the outcomes after the use of this laser in BPH, Soft Tissue Urologic surgery,
Thoracic surgery, Gastroenterology etc.
https://youtu.be/_pof17l4ESA